Details
High Performance Drive Specifically for BLDC Compressors, Heat Pumps & CDUs
Invertek’s high-performance OPTIDRIVE™ CoolVert; designed specifically for machine builders to optimise the performance of BLDC compressors used in Heat Pumps and Condensing Units (CDUs), improving overall system performance and lowering energy costs.
Features:
1. Open Connectivity & Easy Commissioning
- Seamless connectivity with any application controller
- Built in RS485 Modbus RTU
- Bluetooth connectivity available via Optistick Smart
- External TFT keypad available
- Drive status LEDs
- Compact design with through panel mounting
- Wide operating temperature: −20˚C to 60˚C
- IP20 rated front enclosure, IP55 at the rear
- Coldplate version available
- Coated PCBs meet class 3C2 in accordance with EN60713-303
- Built-in EMC filter class C1 in accordance with EN61800-3-2004
- Low harmonic design compliant with; EN61000-3-2, (1 phase 200-230V input), and EN61000-3-12, (3 phase 380-480V input).
- 1 x 200–240V (± 10%): 7.0A, 12A, 16A, 20A All single phase drives with active PFC
- 3 x 380–480V (± 10%): 14A, 18A, 24A
- AC Induction (IM)
- AC Permanent Magnet (PM)
- Brushless DC (BLDC),
- Synchronous Reluctance (SynRM)
- Line Start Permanent Magnet (LSPM)
- Pluggable control and communication terminals
- STO SIL3 Safe Torque Off for system protection, TUV approved
- Programmable, predefined input and output functions:
- Start / Stop (Enable / Disable)
- PTC motor thermal protection (0-10V, 4-20mA)
- Relay (drive healthy / trip)
- Reduces panel size
- Improves thermal management
- Supports improved IP ratings for electronics
- Cold-plate version also available
7. Safe Torque Off (STO)
- Lower Harmonics compliant with:
- EN 61000-3-2: 1-phase Input Drives
- EN 61000-3-12: 3-phase Input Drives
Technical Specifications:
Input Ratings |
Supply Voltage |
200 – 240V ± 10% 380 – 480V ± 10% |
Supply Frequency | 48 – 62Hz | |
Displacement Power Factor | > 0.98 | |
Phase Imbalance | 3% Maximum allowed | |
Inrush Current | < rated current | |
Output Ratings |
Output Power |
200V: 7.0A to 20A 400V: 14A to 75A |
Overload Capacity | 130% rated current for 10s | |
Output Frequency | 0 – 500Hz | |
Acceleration Time | 0.01 – 600 seconds | |
Deceleration Time | 0.01 – 600 seconds | |
Typical Efficiency | > 98% | |
Ambient Conditions | Temperature |
Storage: -40 to 60°C Operating: -20 to 50°C |
Altitude |
Up to 1000m ASL without derating Up to 2000m maximum |
|
Humidity | 95% Max, non condensing | |
Vibration | Conforms to EN61800-5-1 | |
Enclosure | Ingress Protection | Front IP20 Rear (Through Panel Mounting) IP55 |
Coated PCBs | Designed for operation in 3S2/3C2 environments according to IEC 60721-3-3 |
|
Programming | Modbus RTU (RS485) |
Modbus RTU / CAN through terminals and RJ45 port. |
PC Tools | PC Tools software for Diagnostics and parameter configuration (RJ45 port only). |
|
Keypad | Optional Remote Keypad with TFT display for diagnostic and programming | |
Smartphone app | Optitools Mobile | |
Control Specification |
Control Method |
Modbus RTU (RS485) Terminal Control Digital / Analogue Terminal Control PI mode Master / Slave Mode |
PWM Frequency | 4 – 32kHz | |
Stopping Mode | Ramp to stop, Coast to stop | |
Control Modes | Modbus RTU (RS485) Terminal Control Digital / Analogue Terminal Control PI mode Master / Slave Mode |
|
Skip Frequency | 2 skip frequencies, user adjustable | |
Safe Torque Off (STO) | IEC 61800-5-2:2016 | SIL 3 |
UL 61800-5-2 : 2022 | SIL 3 | |
Independent Approval | TUV Rheinland / UL |