Details
The Optidrive P2 offers the perfect combination of high performance together with ease of use to allow even the most demanding applications to be tackled easily.
Designed for fast installation and commissioning, Optidrive P2 provides the most cost effective solution for industry. All Optidrive P2 units provide 150% overload for 60 seconds as standard, ensuring each drive is suitable for Heavy Duty applications, whilst the IP55 enclosed versions ensure the drive is tough enough to survive in industrial environments. Extensive I/O and communications interface capabilities ensure the drive can be integrated quickly and efficiently into a wide variety of control systems with the minimum commissioning time, ensuring rapid start up. Invertek’s simple parameter structure, and carefully selected factory parameter settings ensure that commissioning time is kept to a minimum.
Features:
1. Sensorless Vector Control
Up to 200% torque from zero speed ensures reliable starting and accurate speed control under all load conditions.
2. PM Motor Control
Future proof. Allows upgrade to the latest generation of high efficiency permanent magnet motors.
3. Built-in EMC Filte
An internal filter in every Optidrive P2 saves cost and time for installation.
4. Integral Brake Transistor
Saves space, cost and time for installation
5. Sensorless Vector Control for all Motor Types
- Induction Motors (IM)
- Permanent Magnet Motors (PM)
- Brushless DC Motors (BLDC)
- Synchronous Reluctance Motors (SynRM)
- Line Start PM Motor (LSPM)
6. Options & Software
A range of external EMC filters, brake resistors, input chokes and output filters are available.
7. Optistick Smart Compatible
- Bluetooth
- NFC
IP20 | IP55 | IP66/NEMA 4X Outdoor |
|
|
|
Size & Weight:
Technical Specifications:
Input Ratings |
Supply Voltage |
200 – 240V ± 10% 380 – 480V ± 10% 500 – 600V ± 10% |
|
Supply Frequency | 48 – 62Hz | ||
Displacement Power Factor | > 0.98 | ||
Phase Imbalance | 3% Maximum allowed | ||
Inrush Current | < rated current | ||
Power Cycles | 120 per hour maximum, evenly spaced | ||
Output Ratings |
Output Power |
230V 1 Phase: 0.75–7.5kW / 1–10HP 230V 3 Phase: 0.75–75kW / 1–100HP 400V 3 Phase: 0.75–250kW 460V 3 Phase: 1–350HP 575V 3 Phase: 0.75–110kW / 1–150HP |
|
Overload Capacity | 150% for 60 seconds | ||
Output Frequency | 0 – 500Hz, 0.1Hz resolution | ||
Typical Efficiency | > 98% | ||
Acceleration Time | 0.01 – 600 seconds | ||
Deceleraton Time | 0.01 – 600 seconds | ||
Typical Efficiency | 98% | ||
Ambient Conditions | Temperature |
Storage: -40 to 60°C Operating: -10 to 50°C |
|
Altitude |
Up to 1000m ASL without derating Up to 2000m maximum UL approved Up to 4000m maximum (non UL) |
||
Humidity | 95% Max, non condensing | ||
Vibration | Conforms to IEC 60068-2-6 Sinusoidal Vibration 10 - 57Hz @ 0.075mm Pk 57 - 150Hz @ 1g Pk |
||
Enclosure | Ingress Protection | IP20, IP55, IP66 | |
Programming | Keypad | Built-in keypad as standard Optional remote mountable keypad |
|
Display | Built-in multi language text display | ||
PC | OptiTools Studio | ||
Control Specification |
Control Method |
V/F Voltage Vector Energy Optimsied V/F 3GV Sensorless Vector Speed Control 3GV Sensorless Vector Torque Control Closed Loop (Encoder) Speed Control Closed Loop (Encoder) Torque Control PM Vector Control BLDC Control Synchronous Reluctance |
|
PWM Frequency | 4 – 32kHz Effective | ||
Stopping Mode | Ramp to stop: User Adjustable 0.1 – 600 secs Coast to stop |
||
Braking |
Motor Flux Braking Built-in braking transistor |
||
Skip Frequency | Single point, user adjustable | ||
Setpoint Control | Analog Signal | 0 to 10 Volts 10 to 0 Volts −10 to 10 Volts 0 to 20mA 20 to 0mA 4 to 20mA 20 to 4mA |
|
Digital |
Motorised Potentiometer (Keypad) Modbus RTU CANopen |
||
Fieldbus | Built in | CANopen | 125–1000 kbps |
Modbus RTU | 9.6 - 115.2 kbps selectable 8N1, 8N2, 8E1, 8O1 |
||
Optional | Other | PROFIBUS DP (DPV1) PROFINET IO DeviceNet EtherNet/IP EtherCAT Modbus TCP |
|
I/O Specification | Power Supply |
24 Volt DC, 100mA, Short Circuit Protected 10 Volt DC, 10mA for Potentiometer |
|
Programmable Inputs |
5 Total as standard (Optional additional 3) 3 Digital (Optional additional 3) 2 Analog / Digital Selectable |
||
Digital Inputs |
Opto - Isolated 8 – 30 Volt DC, internal or external supply Response time < 4ms |
||
Analog Inputs |
Resolution: 12 bits Response time: < 4ms Accuracy: < 1% full scale Parameter adjustable scaling and offset |
||
PTC Input |
Motor PTC / Thermistor Input Trip Level : 3kΩ |
||
Programmable Outputs |
4 Total (Optional additional 3) 2 Analog / Digital 2 Relays (Optional additional 3) |
||
Relay Outputs |
Maximum Voltage : 250 VAC, 30 VDC Switching Current Capacity : 5A AC , 5A DC |
||
Analog Outputs | 0 to 10 Volt 0 to 20mA 4 to 20mA |
||
Application Features |
PI Control |
Internal PID Controller Multi Setpoint Select Standby / Sleep Mode Boost Function |
|
Hoist Mode |
Dedicated Hoist Mode Motor Holding Brake Pre-Torque & Control Over Limit Protection |
||
Maintenance & Diagnostics | Fault Memory | Last 4 Trips stored with time stamp | |
Data Logging |
Logging of data prior to trip for diagnostic purposes : Output Current, Drive Temperature, DC Bus Voltage | ||
Maintenance Indicator |
Maintenance Indicator with user adjustable maintenance interval Onboard service life monitoring |
||
Monitoring | Hours Run Meter Resettable & Non Resettable kWh meters Cooling Fan Run Time |
||
Standards Compliance | Low Voltage Directive | 2014/35/EU | |
EMC Directive | 2014/30/EU | ||
Additional Conformance | UL, cUL, EAC, RCM | ||
Marine Certification | DNV Type Approval | ||
Environmental |
IP20 products: Designed for use in environments where the level of chemically active substances does not exceed the limits of class 3C2, and where the levels of mechanically active substances do not exceed the limits of class 3S2 according to IEC60721-3. IP55 & IP66 products: Designed for use in environments where the level of chemically active substances does not exceed the limits of class 3C3, and where the levels of mechanically active substances do not exceed the limits of class 3S3 according to IEC60721-3. |
View more about INVERTEK DRIVES OPTIDRIVE-P2 Series on main site