Details
Focused on ease of use, Optidrive E3 provides unrivalled simplicity of installation, connection and commissioning, allowing the user to benefit from precise motor control and energy savings within minutes.
Specifications:
1. Low Power Applications
Dedicated to low power applications, Optidrive E3 combines innovative technology, reliability, robustness and ease of use in a range of compact IP20 & IP66 enclosures.
2. Simple Commissioning
14 parameter basic setup. Default settings suitable for most applications. Contactor style connection for simple wiring.
3. Optidrive E3 IP66
Environmentally protected, IP66 rated models can be mounted directly on your processing equipment.
4. Washdown Ready
With a sealed ABS enclosure and corrosion resistant heatsink, Optidrive E3 IP66 models are ideal for high-pressure washdown applications.
5. On-drive Control
IP66 models feature optional, convenient controls for speed control, REV/OFF/FWD and Power ON/OFF, complete with safety lock.
6. Single Phase Motor Control
Optidrive E3 for Single Phase Motors provides accurate speed control of single phase PSC or shaded pole motors. Special boost phase ensures reliable starting, initially ramping the motor voltage up to rated voltage whilst maintaining a fixed starting frequency, before reducing the frequency and voltage to the desired operating point.
Features:
- 110–115V and 200–240V models
- Small mechanical envelope
- IP 20 & IP66 Protection
- Rugged industrial operation
- Fast setup, and simple operation with 14 basic parameters
- Unique motor control strategy optimised for single phase motors
- Motor current and rpm indication
- Built in PI control, EMC filter (C1) & brake chopper
- Application macros for industrial, fan and pump operation
- Bluetooth connectivity
IP20 | IP66/NEMA 4X Outdoor |
|
|
Size & Weight:
Technical Specifications:
Input Ratings |
Supply Voltage |
100 – 115V ± 10% 200 – 240V ± 10% 380 – 480V ± 10% |
||
Supply Frequency | 48 – 62Hz | |||
Displacement Power Factor | > 0.98 | |||
Phase Imbalance | 3% Maximum allowed | |||
Inrush Current | < rated current | |||
Power Cycles | 120 per hour maximum, evenly spaced | |||
Output Ratings |
Output Power |
110V 1 Ph Input: 0.5–1.5HP (230V 3 Ph Output) 230V 1 Ph Input: 0.37–4kW (0.5–5HP) 230V 3 Ph Input: 0.37–18.5kW (0.5–25HP) 400V 3 Ph Input: 0.75–37kW (1–50HP) 460V 3 Ph Input: 1–50HP |
||
Overload Capacity |
150% for 60 Seconds 175% for 2.5 seconds |
|||
Output Frequency | 0 – 500Hz, 0.1Hz resolution | |||
Typical Efficiency | > 98% | |||
Ambient Conditions | Temperature |
Storage: -40 to 60°C Operating: -20 to 50°C |
||
Altitude |
Up to 1000m ASL without derating Up to 2000m maximum UL approved Up to 4000m maximum (non UL) |
|||
Humidity | 95% Max, non condensing | |||
Vibration | Conforms to EN61800-5-1 | |||
Enclosure | Ingress Protection | IP20, IP66 | ||
Programming | Keypad | Built-in keypad as standard Optional remote mountable keypad |
||
Display | 7 Segment LED | |||
PC | OptiTools Studio | |||
Control Specification |
Control Method |
Sensorless Vector Speed Control PM Vector Control BLDC Control Synchronous Reluctance |
||
PWM Frequency | 4 – 32kHz Effective | |||
Stopping Mode | Ramp to stop: User Adjustable 0.1 – 600 secs Coast to stop |
|||
Braking |
Motor Flux Braking Built-in braking transistor (not frame size 1) |
|||
Skip Frequency | Single point, user adjustable | |||
Setpoint Control | Analog Signal | 0 to 10 Volts 10 to 0 Volts 0 to 20mA 20 to 0mA 4 to 20mA 20 to 4mA |
||
Digital |
Motorised Potentiometer (Keypad) Modbus RTU CANopen |
|||
Fieldbus | Built in | CANopen | 125–1000 kbps | |
Modbus RTU | 9.6–115.2 kbps selectable | |||
I/O Specification | Power Supply |
24 Volt DC, 100mA, Short Circuit Protected 10 Volt DC, 10mA for Potentiometer |
||
Programmable Inputs |
4 Total 2 Digital 2 Analog / Digital Selectable |
|||
Digital Inputs |
8 – 30 Volt DC, internal or external supply Response time < 4ms |
|||
Analog Inputs |
Resolution: 12 bits Response time: < 4ms Accuracy: ± 2% full scale Parameter adjustable scaling and offset |
|||
Programmable Outputs |
2 Total 1 Analog / Digital 1 Relay |
|||
Relay Outputs |
Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity : 6A AC, 5A DC |
|||
Analog Outputs | 0 to 10 Volt | |||
Application Features |
PI Control |
Internal PI Controller Standby / Sleep Function |
||
Fire Mode |
Bidirectional Selectable Speed Setpoint (Fixed / PI / Analog / Fieldbus) |
|||
Maintenance & Diagnostics | Fault Memory | Last 4 Trips stored with time stamp | ||
Data Logging |
Logging of data prior to trip for diagnostic purposes: Output Current Drive Temperature DC Bus Voltage |
|||
Monitoring | Hours Run Meter | |||
Standards Compliance | Low Voltage Directive | Adjustable speed electrical power drive systems. EMC requirements |
||
EMC Directive | 2014/30/EU Cat C1 according to EN61800-3:2004 |
|||
Machinery Directive | 2006/42/EC |
|||
Conformance | CE, UL, RCM | |||
Environmental |
IP20 products: Designed for use in environments where the level of chemically active substances does not exceed the limits of class 3C2, and where the levels of mechanically active substances do not exceed the limits of class 3S2 according to IEC60721-3. IP66 products: Designed for use in environments where the level of chemically active substances does not exceed the limits of class 3C3, and where the levels of mechanically active substances do not exceed the limits of class 3S3 according to IEC60721-3. |
|||
View more about INVERTEK DRIVES Optidrive E3 Series on main site